Liquid turbine flowmeter

Liquid turbine flowmeter
  • Detailed Description

Technical specifications

The sensors of DN4—DN40 caliber are connected by a threaded,and the maximum working pressure is 6.3MPa.;

The sensors of DN50—DN200 caliber are connected by a flange,and the maximum working pressure is 2.5MPa.;

DN4—DN10 caliber sensors have front and rear straight pipe sections.

For sensors of caliber above DN15,our company can match the front and rear straight pipe  sections

Medium    temperature:-20~+120℃ .

Ambient    temperature:-20   +65℃ .

Power     supply:voltage+6-24VDC,current:≤10mA.

13.6V/0.3mA when the battery is powered.485 communication current increased by 0.6mA. Transmission distance:The distance from the sensor to the flowmeter can reach 1000m.

Flow range

 

Instrument caliber (mm)

Measuring range (m³/h)

Output frequency range(Hz,L)

DN 4

0.04~0.25

177..8~1111

DN6

0.1~0.6

227.8~1366

DN 10

0.2~1.2

100.0~600

DN 15

0.6~6

138.3~1383

DN 20

0.8~8

133.3~1333

DN 25

1~10

58.9~588

DN 32

1.5~15

625~625

DN 40

2~20

42.8~427

DN 50

4~40

30.0~300

DN 65

7~70

23.5~235

DN 80

10~100

16.9~169

DN 100

20~200

23.8~238

DN 125

25~250

21.5~215

DN 150

30~300

18.3~183

DN 200

80~800

26.7~266