PRODUCTS
Performance specifications
1.Accuracy:The accuracy of the system after temperature and pressure corection;
2.Standard state conditions:P=101.325kPa,T=293.15K 3.Conditions of use:
Ambient temperature:-30℃~+65℃ Relative humidity:5%~95%~
Working power suppy:AExternal power suppy:+24VDC±15%,ripple<5%,suitable for 4~20mA output,pulse output,alarm output,RS-485,etc.;
B.Internal power supply:1 set of 3.6V lithium battery(ER26500),when the voltage is lower than 3.0V,an undervoltage indication appears.
Flow range
|
Model |
Nominal diameter DN(mm) |
Flow range: (m³/h) |
Nominal pressure (MPa) |
Accuracy level |
Shell material |
|
LUXB-015 |
15 |
1.0~10 |
Stainless steel 1Cr18Ni9Ti Or aluminum alloyZL101 |
||
|
LUXB-020 |
20 |
1.5~15 |
1.6 |
||
|
LUXB-025 |
25 |
3.0~30 |
|||
|
LUXB-032 |
32 |
6.0~60 |
2.5 |
||
|
LUXB-040 |
40 |
7.0~70 |
|||
|
LUXB-050 |
50 |
10~130 |
1 |
||
|
LUXB-065 |
65 |
25~300 |
|||
|
LUXB-080 |
80 |
30~400 |
4 |
1.5 |
|
|
LUXB-100 |
100 |
50~800 |
|||
|
LUXB-125 |
125 |
80~1000 |
2.5 |
||
|
LUXB-150 |
150 |
150~1500 |
|||
|
LUXB-200 |
200 |
240~3600 |
6.3 |
Copyright © Weihai Lanke flow equipment Co., LTD Disclaimers: Some pictures and text from the Internet, if there is infringement, please contact delete.Website construction: Henghui Technology