PRODUCTS
Scope of application
Intelligent electromagnetic flow sensoris a high-intelligence and high-reliability
flowmeter developed using international advanced technology.It can not only be used for general process detection,but also for the measurement of mineral pulp,pulp and pasteliquids.It is widely used in petroleum,chemical industry,iron and steel,food,
electric power,papermaking,water conservancy,water supply and drainage,water administration and water resources industries.
|
Nominal diameter |
DN6-3000mm |
|
Nominal pressure |
0.6、1.0、1.6、4.0MPa(High pressure can be processed according to user requirements) |
|
Accuracy |
士0.2%土0.5%(Indication error) |
|
Measurement range |
0~1m/s to 0~10m/s |
|
Medium temperature |
Body type-10℃~+80'C;All-in-one-10℃~+80℃ |
|
Ambient temperature |
.-25℃~+60℃ |
|
Ambient humidity |
5~100%RH(Relative humidity) |
|
Dielectric conductivity |
over than 20uS/cm |
|
Installation method |
Body type、All-in-one |
|
Shell protection level |
Sensors IP65 and IP68 are optional(IP65:dust-tightwater-proof type, which allows the faucet to spray water on the instrument from any direction;IP68:dust-tight,submersible type,which can work in water for a long time)converter IP65 |
|
Electrode structure |
Three-electrode structure,scraper electrode structure |
|
Maxmum temperature of the medium under test |
The neoprene lining is up to 80℃,the polyurethane lining is up to 80℃,the polytetrafluoroethylene lining is up to 180℃,and the high temperature resistant rubber lining is up to 120℃. |
|
Sensor output signal |
0-0.2mVp-p to 0-2mVp-P |
|
Electrode material |
Stainless steel Ocrl8Nil2Mo2Ti,hastelloy B,C,titanium Titantalum (Ta),stainless stee coated tungsten carbide,special |
|
Explosion-proof sign |
Exd II CT6,Exd IⅡ BT4 |
|
Process connection |
M20x 1.5 external thread/DN25 flange connection/other |
Copyright © Weihai Lanke flow equipment Co., LTD Disclaimers: Some pictures and text from the Internet, if there is infringement, please contact delete.Website construction: Henghui Technology